Solution #0246 · Healthcare · Industry-specific

Same-Device Clinical Evaluation Literature Dossier — Search Trails, Paper-by-Paper Grading, Relevance Checks

Helps R&D turn the literature dossier into a paper-by-paper verification record that can be traced back and re-checked

Score
10
Internal scoring scale
Roles
R&D
Frontline role
Industry
Healthcare
Industry-specific
Maturity
Live
Validated in practice
01 — Business fit

Who should use it, and when

Built for R&D and regulatory affairs staff doing same-device clinical evaluation in healthcare — especially when a literature search report cites dozens of papers yet a fair share cannot clearly be tied to the comparison device. It puts the search process, paper-by-paper grading, and relevance checks into one dossier, so every citation in the report can be traced to its source and the reasoning behind it. The source tags the role as R&D.

02 — Key steps

The key moves that make it work

1
Leave a trail of search strings and dates

For every search, record the database name, the search string, the date, and the number of hits, and export the raw results to a separate archive. Every paper cited in the report must map back to one of those searches — no backfilling after the fact.

2
Set the grading scorecard first

Before screening, write the grading dimensions into one table — study type, sample size, follow-up duration, control setup — and score every paper against the same set. Once set, the criteria do not change midway; if they do, the reason must be written down.

3
Check device details item by item

For each paper, verify the comparison device's name, model and specifications, intended use, and instructions for use, and record a match or mismatch for each item. Never substitute words like 'similar' or 'close' for an actual check.

4
Tag every excerpt with page and paragraph

Every excerpt in the dossier notes which paper, which page or paragraph it came from, plus the verifier's name and verification date. The report cites only dossier entry numbers, so a reader can go back to the dossier and locate the original text.

5
List discrepant papers separately

Do not simply delete papers with weak relevance. Put them in a separate table stating the differences, the treatment (excluded, or kept as supporting evidence), and the reason — so when someone asks why a few papers disappeared, the answer is ready.

TAKEAWAY
The value of the dossier is that it can be re-checked
This dossier does not exist to grow the paper count; it exists so that every keep-or-drop decision has a search record, a scoring basis, and a named verifier — so someone else can pick it up and re-check it.
03 — Risks & pitfalls

What to know before you start

Risk 1 · Grading conclusions vary by reviewerHowever detailed the grading table, judgment remains, and two reviewers may score the same paper differently. Without a second-person review or a pilot scoring of a few papers to calibrate the scale, the grading rarely survives external review.
Risk 2 · Incomplete comparator device dataRelevance checks depend on complete comparator data — specifications, intended use, and more. When information is missing, it is tempting to call a paper relevant because the names look alike and to write uncertainty down as certainty. That is where this fails most often.
Risk 3 · Dossier versions go staleA search trail is only a snapshot of one point in time. If the report changes or new searches are added and the dossier numbers and dates are not updated in step, dossier and report stop matching, and reviewers cannot tell which version governs.