Solution #0327 · Energy & Utilities · Industry-specific

Integrated energy use diagnosis — attributing energy anomalies and recommending retrofits based on sub-metering data

Help sales work out the breakdown data when a customer can't say where their energy goes

Score
5.3
Internal scoring scale
Roles
Sales
Frontline role
Industry
Energy & Utilities
Industry-specific
Maturity
Live
Validated in practice
01 — Business fit

Who should use it, and when

For sales roles in the energy and public utilities industry: a customer expresses interest in an energy-saving retrofit but can't say where last year's energy went. This solution uses sub-metering data to break usage down by equipment and time period, flags the mismatches, and only then discusses retrofits. The source lists it as Industry-specific and Live, but there are no measured results yet.

02 — Key steps

The key moves that make it work

1
First check the on-site metering points

Confirm whether the customer has installed meters on main energy-using equipment or branch circuits, and whether the sampling interval and data retention period are adequate. If there's only a main meter, add branch meters first or use manual readings as a stopgap; otherwise attributing usage by category is out of the question.

2
Collect a full year of data

Pull sub-metered energy records covering a complete year, and clearly mark any missing months in the report. With only a few months of data, seasonal changes and shutdown maintenance periods are easily mistaken for anomalies.

3
Break down by equipment and time period

Break usage down by equipment, area, and shift, then compare it with output or revenue to find periods where usage and output don't match. The output of this step is a list of suspects, not a conclusion.

4
Verify anomalies back on site

Go through the list item by item with the customer's equipment manager on site to look at operating conditions, shift arrangements, and equipment age. Write confirmed items into the retrofit recommendation; unverified ones stay on the list as to be checked.

5
Deliver recommendations in two categories

List separately what the customer can change themselves (operating hours, standby power-off, setpoint adjustments) and what needs professional assessment (equipment replacement, system retrofits); for each item, state the basis for the judgment and how the customer can verify it themselves.

TAKEAWAY
Have the data first, then talk about retrofits
When a customer can't say where their energy goes, don't give a retrofit plan right away; first complete the sub-metering and check the data thoroughly, then discuss what and where to change.
03 — Risks & pitfalls

What to know before you start

Risk 1 · Insufficient metering pointsWhen the customer only has a main meter and branch meter coverage is low, anomalies can only be located at the overall level, and you can't write recommendations for specific equipment; what the solution can deliver is noticeably reduced.
Risk 2 · Poor data qualityMeter failures, errors and omissions in manual readings, and missing months shift the energy baseline and cause normal fluctuations to be judged as anomalies; the retrofit recommendations that follow also go off course.
Risk 3 · Attribution going beyond the evidenceA usage anomaly may come from changes in output, weather, or shift arrangements, not from equipment. The data only shows where things don't match; jumping straight to an energy-saving conclusion easily points to the wrong retrofit direction.